TransSECS Devices - Scripting for PLC Servers
To write a value to a server in the devices the format is:
/Devices/[DeviceNodeName]_Servers/[ServerName]→[setValue]
For example, to set the integer value 2 to a server called ModbusWord under the ModbusTCP node use:
/Devices/ModbusTCP_Servers/ModbusWord->setIntValue(2);
TransSECS is thread safe and so you can create threads in a script. Here's an example that creates a thread before setting the value of a Modbus server.
var Thread = Java.type("java.lang.Thread"); var Runnable = Java.type("java.lang.Runnable"); // declare our thread this.thread = new Thread(new Runnable(){ run: function () { /Devices/ModbusTCP_Servers/ModbusWord->setIntValue(2); print("printed from a separate thread"); } }); // start our thread this.thread.start();
Register for Connection Status Notification in TransSECS Host Application
In a GEMHost application the TransSECS controller publishes the status of the connection.
To register for this, add a “Startup Trigger” from the “Demo Servers”
Register for the notification in the “script” field. Here the notification is just printed to the display.
var TransSecsController = Java.type("com.ergotech.transsecs.secs.TransSecsController"); var ConnectionStatusListener = Java.type("com.ergotech.transsecs.secs.host.ConnectionStatusListener"); print("Startup Trigger"); host=TransSecsController.findController("GEMHost"); // create the connection status listener var connectionStatusListener = new ConnectionStatusListener() { connectionStatusChanged : function (connectionStatus, comment) { print ("Current Connection Status " + connectionStatus + " Status String \"" + comment + "\""); } }; // add this to the host host.addConnectionStatusListener(connectionStatusListener); print("Connection Status Trigger Registered");
The details of the connection status are described here
Sending a List to PLC Registers
If a message is received from the host contains a list of variable length it's easy to split this list and place it in registers on the PLC.
In TransSECS, give the list a name, here “SlotIDList” and mark it as Publish. Do not set a Device and Tagname.
In a tag-based PLC, such as an Ethernet-IP PLC. You can write to elements of an array tag.
If your device is called “EIPPLC” and you want to write the values to an array “StringArray” using the server “SlotIDList” then the code would look like this:
for (id =0 ; id < incomingValue.size() ; id++ ) { /Devices/EIPPLC_Servers/SlotIDList->setVariableName("StringArray["+id+"]"); // set the element /Devices/EIPPLC_Servers/SlotIDList->setStringValue(incomingValue.get(id).getStringValue()); // send the value } /Devices/EIPPLC_Servers/NumberOfSlotIds->setIntValue(incomingValue.size()); // set the list length
The last line of the script puts the length of the list into a server called “NumberOfSlotIds”. After receipt, the PLC should reset the “NumberOfSlotIds” variable so that it will change when the message is next received.
For a register-based PLC, such as a FINs PLC and a device called “FINSPLC” the equivelent code would be:
var baseRegister = 100; var stringLength = 8; for (id =0 ; id < incomingValue.size() ; id++ ) { /Devices/FINSPLC_Servers/SlotIDList->setAddress("" + (baseRegister + stringLength*id)); /Devices/FINSPLC_Servers/SlotIDList->setStringValue(incomingValue.get(id).getStringValue()); } /Devices/FINSPLC_Servers/NumberOfSlotIds->setIntValue(incomingValue.size());