**How to Get an SVID Value from the Tool** - Start the SECS Tester - Double-Click on "Set Up Communications to Tool" to open the Communications Setup Dialog - The default tool configuration will be shown. You can change the tool name so that this configuration will be saved as a new tool setup. - Enter the HSMS Port (or SECS I Port, a port number < 255) - Enter the Device ID - Enter the new tool name - Save the configuration by pressing the Save button, then the close button - Select the new tool configuration from the combo box. You should see the tool configuration printed out in the text field on the right. - Connect to the tool - Press "Connect To Tool" button to send an S1F13 to the tool. - If the communications was successful you will see a response from the tool. - Go online-remote with the tool - Be sure the tool is ready to go online with this host and is allowing remote communications. - Press "Request ONLINE" button to send an S1F17 to the tool. - If the online request was successful you will see an S1F18 response with a reply other than "1" (which means it cannot go online). - Once the tool is ONLINE-REMOTE you can get a list of SVIDs and request the current value of any of them. - Double-Click "Check SVID Values" to launch the SVID Report dialog - Click on the "Get List of SVIDs" button to send an S1F11 to the tool - If the tool has SVIDs, these VIDs will show up in the SVID List combo box, alphabetically by SVID name - Select an SVID and press the "Get Current Value" to send an S1F3 to the tool - The current value will be displayed below the "Get Current Value" button