transsecsscripts [2020/07/21 00:43] – wikiadmintranssecsscripts [2020/09/22 10:15] (current) – wikiadmin
Line 11: Line 11:
 For this example we have added a String VID called "ProcessStatus" to the ModbusPLCTool. We have added a Modbus 4X register to read an integer value from the PLC. We will convert the value read from the Modbus 4X register to a String and write this value to the ProcessStatus VID. This code is entered in the Modbus 4X register's script. For this example we have added a String VID called "ProcessStatus" to the ModbusPLCTool. We have added a Modbus 4X register to read an integer value from the PLC. We will convert the value read from the Modbus 4X register to a String and write this value to the ProcessStatus VID. This code is entered in the Modbus 4X register's script.
  
-<code>+<code javascript>
 var TransSecsController = Java.type("com.ergotech.transsecs.secs.TransSecsController"); var TransSecsController = Java.type("com.ergotech.transsecs.secs.TransSecsController");
 var SecsFormat20 = Java.type("com.ergotech.secs.SecsFormat20"); var SecsFormat20 = Java.type("com.ergotech.secs.SecsFormat20");
 var SecsFormat54 = Java.type("com.ergotech.secs.SecsFormat54"); var SecsFormat54 = Java.type("com.ergotech.secs.SecsFormat54");
  
- +status=incomingValue.getIntValue(); //the PLC register value 
-//convert integer value to String and update the VID on a value change+//convert integer value to a String and update the VID on a value change
 //values are 0=Uninitialized 1=Ready To Start 2=Running 3=Completed //values are 0=Uninitialized 1=Ready To Start 2=Running 3=Completed
-//if value is out of range, set status to "Undefined"+//if value is out of range, set it to "Undefined"
 try { try {
- status=incomingValue.getIntValue(); //the PLC register value 
- stringValue="Undefined"; 
  switch (status) {  switch (status) {
    case 0:    case 0:
Line 35: Line 33:
    case 3:      case 3:  
      stringValue="Completed";      stringValue="Completed";
-     break; +      default: 
- }+         stringValue="Undefined"; 
 +  }
   tool=TransSecsController.findController("ModbusPLCTool");   tool=TransSecsController.findController("ModbusPLCTool");
   gh = tool.getGemHandler();   gh = tool.getGemHandler();
-  gh.setValue("ProcessStatus",new SecsFormat20(stringValue));  +   
- +  //get the current VID value and set this new value if this is a change 
 +  currentValue = gh.getValue("ProcessStatus").getStringValue(); 
 +  
 +  //check that the value has changed before writing to the VID 
 +  if (!(currentValue.equals(stringValue))){ 
 +    gh.setValue("ProcessStatus",new SecsFormat20(stringValue));  
 +  } 
 } catch (e)  { } catch (e)  {
      print("Error converting register value to String");      print("Error converting register value to String");
-     print(e.stack));  +     print(e.stack);  
 } }
  
 </code> </code>
  
 +=== Additional Examples ===
  
 +[[scriptingexamples|TansSECS and MIStudio JavaScript Examples]]
  
-more examples coming soon!+[[devices|TransSECS Devices JavaScript Examples]]