scripting_for_plc_servers

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
scripting_for_plc_servers [2020/09/08 19:22]
wikiadmin
scripting_for_plc_servers [2021/09/10 16:09] (current)
wikiadmin
Line 1: Line 1:
-==== TransSECS Devices - Scripting for PLC Servers ====+===== TransSECS Devices - Scripting for PLC Servers =====
  
 To write a value to a server in the devices the format is: To write a value to a server in the devices the format is:
Line 30: Line 30:
 </code> </code>
  
-**Set a value to a field in a message and send the message**+==== Set a value to a field in a message and send the message ====
  
  
Line 43: Line 43:
 </code> </code>
  
-Here's a more concreted example. In an S2F42/S2F50 reject response set the CPName to indicate which parameter is in error:+Here's a more concrete example. In an S2F42/S2F50 reject response set the CPName to indicate which parameter is in error:
  
 <code javascript> <code javascript>
Line 65: Line 65:
 </code> </code>
  
-**Register for Connection Status Notification in TransSECS Host Application**+==== Register for Connection Status Notification in TransSECS Host Application ====
  
 In a GEMHost application the TransSECS controller publishes the status of the connection. In a GEMHost application the TransSECS controller publishes the status of the connection.
Line 98: Line 98:
 The details of the connection status are [[programmatic_host_connection_status|described here]] The details of the connection status are [[programmatic_host_connection_status|described here]]
  
-**Sending a List to PLC Registers**+==== Writing a List to PLC Registers ====
  
 If a message is received from the host contains a list of variable length it's easy to split this list and place it in registers on the PLC. If a message is received from the host contains a list of variable length it's easy to split this list and place it in registers on the PLC.
Line 134: Line 134:
 </code> </code>
  
-**Reading a Variable Length List from a PLC and updating a VID**+==== Reading a Variable Length List from a PLC and updating a VID ====
  
 The most challenging part of reading the list from the PLC is managing the length of the list. The most challenging part of reading the list from the PLC is managing the length of the list.
Line 184: Line 184:
 0;  // update the server with a zero... 0;  // update the server with a zero...
 </code> </code>
 +
 +If the PLC Device supports an Array type, you can use this value directly in the Device Name/Tag Name dropdown.  The values from the array will be automatically converted from the type in the array to the SecsFormat type.
 +
 +For a ModbusArray, the conversion is as follows:
 +
 +{{:pasted:20210129-100944.png}}
 +
 +Unsigned Word - SecsFormat52
 +Signed Word - SecsFormat54 
 +Unsigned Double Word - SecsFormat50
 +Signed Double Word - SecsFormat50
 +Float - SecsFormat44
 +Coil - SecsFormat11
 +Discrete - SecsFormat11
 +
 +For an S7 Array the conversions X,B,W,I,D all convert to SecsFormat5. R (real) convert to SecsFormat44 and S (String) to SecsFormat20.
 +
 +For improved control over the conversion, the SecsFormat00 can be created in a script.
 +
 +In this example we create a SecsFormat00 containing signed integers  - SecsFormat34
 +<code javascript>
 +var TransSecsController = Java.type("com.ergotech.transsecs.secs.TransSecsController");
 +var SecsFormat34 = Java.type("com.ergotech.secs.SecsFormat34");
 +var SecsFormatValueObject = Java.type("com.ergotech.secs.gem.SecsFormatValueObject");
 +var SecsFormat00 = Java.type("com.ergotech.secs.SecsFormat00");
 +
 +listValue = new SecsFormat00();
 +try {
 +
 +        secsInterface=TransSecsController.findController("PLCTool");
 +        gh = secsInterface.getGemHandler();
 +
 +        for (id =0 ; id < incomingValue.size() ; id++ ) {
 +            listValue.add(new SecsFormat34(incomingValue.get(0).getIntValue()));
 +        }
 +        print ("List "+ listValue);
 +        gh.setValue("ListVID",listValue);
 +
 +    }
 +} catch ( e ) {
 +    print ("Error " + e );
 +}
 +new SecsFormatValueObject(listValue);
 +</code>
 +
 +==== Reading a File and Storing as Binary Data in the PLC ====
 +
 +This example uses the Melsec Binary (MelsecBinary) server.  It reads a file from the disk, compresses the file and sends it to the server.
 +
 +
 +<code>
 +var Deflater = Java.type("java.util.zip.Deflater");
 +var Inflater = Java.type("java.util.zip.Inflater");
 +var Files = Java.type("java.nio.file.Files");
 +var BinaryValueObject = Java.type("com.ergotech.vib.valueobjects.BinaryValueObject");
 +var LongValueObject = Java.type("com.ergotech.vib.valueobjects.LongValueObject");
 +var arrayOfBytes = Java.type("byte[]");
 +
 +recipe = Files.readAllBytes(java.nio.file.Paths.get("DemoPPBody.rcp"));
 +// Compress the bytes
 +output = new arrayOfBytes(2000);
 +compresser = new Deflater();
 +compresser.setInput(recipe);
 +compresser.finish();
 +compressedDataLength = compresser.deflate(output);
 +compresser.end();
 +outArray = new arrayOfBytes(compressedDataLength);
 +java.lang.System.arraycopy(output, 0, outArray, 0, compressedDataLength);
 +
 +// save the length of the compress recipe to the PLC using a server called "CompressedRecipeLength"
 +CompressedRecipeLength->setValueObject(new LongValueObject(compressedDataLength));
 +
 +new BinaryValueObject(outArray);  // will be writen to the server
 +</code>
 +
 +The inverse of the above code reads the bytes from the PLC and stores them to a file.
 +
 +<code>
 +var Deflater = Java.type("java.util.zip.Deflater");
 +var Inflater = Java.type("java.util.zip.Inflater");
 +var Files = Java.type("java.nio.file.Files");
 +var BinaryValueObject = Java.type("com.ergotech.vib.valueobjects.BinaryValueObject");
 +var StringValueObject = Java.type("com.ergotech.vib.valueobjects.StringValueObject");
 +var arrayOfBytes = Java.type("byte[]");
 +
 +// read the length of the compress recipe from the PLC using a server called "CompressedRecipeLength"
 +CompressedRecipeLength->triggerRead();  // force an update
 +compressedDataLength = CompressedRecipeLength->getIntValue(); // and read the latest value.
 +
 +java.lang.System.out.println  (" Compressed DataLength " + compressedDataLength);
 +// Compress the bytes
 +output = new arrayOfBytes(2000);
 +inflater = new Inflater();
 +buf = incomingValue.getBinaryValue();
 +
 +inflater.setInput(buf,0,compressedDataLength);  // assumes that the compressed data length is always less than the length read from the server (setLength))
 +
 +resultLength = inflater.inflate(output);
 +inflater.end();
 +
 +// trim the array to the size of of the output
 +outArray = new arrayOfBytes(resultLength);
 +java.lang.System.arraycopy(output, 0, outArray, 0, resultLength);
 +
 +Files.write(java.nio.file.Paths.get("DemoPPBody.rcp.out"), outArray);
 +
 +</code>
 +