| **Modbus Register Addresses** | **Modbus Register Addresses** | ||
| + | Modbus address follow the standard Modbus register scheme. | ||
| **EtherNetIP Register Addresses** | **EtherNetIP Register Addresses** | ||
| + | |||
| + | EtherNetIP is based on tag names. | ||
| + | |||
| + | **Siemens S7 PLCs** | ||
| + | |||
| + | There are three primary families of the S7 PLC. S7-1200, S7-300 and S7-1500 (the S7-200 also supported). | ||
| + | |||
| + | To support the different S7 PLCs, the "TSAP dst" property needs to be changed to match the PLC type and configuration. This is an expert property. | ||
| + | |||
| + | S7-1200 | ||
| + | The S7-1200 is usually addressed with the TSAP 02 01 (binary). | ||
| + | |||
| + | S7-300 & S7-1500 | ||
| + | |||
| + | The S7-1500 uses that same configuration as the S7-300 | ||
| + | |||
| + | The S7-300 is usually addressed with the TSAP 03 02 (binary). | ||
| + | |||
| + | Additional information is available here: | ||
| + | |||
| + | https:// | ||
| + | |||
| + | **S7 Addressing** | ||
| + | |||
| + | S7 (and S5) PLCs have the following address structure. | ||
| + | |||
| + | Supported memory types are: I, | ||
| + | Supported data types are: X, | ||
| + | |||
| + | Scalar types can have bit numbers added, so, for example, DB8:D80.11 and MW11.1 are valid addresses. | ||
| + | |||
| + | Further register examples: | ||
| + | |||
| + | < | ||
| + | DB8:S86.50 | ||
| + | DB8:D80.11 | ||
| + | DB8:I80.11 | ||
| + | DB8:R2 | ||
| + | DB8:D8 | ||
| + | DB8:D8.2 | ||
| + | DB8:S20.50 | ||
| + | DB8:I0.2 | ||
| + | DB8:I80 | ||
| + | DB8:W80.11 | ||
| + | DB8:W0.2 | ||
| + | DB8:W80 | ||
| + | DB8:X0.2 | ||
| + | DB8:X6.11 | ||
| + | DB8:X6.2 | ||
| + | |||
| + | MS11.7 | ||
| + | FB2 | ||
| + | QI21 | ||
| + | AI21 | ||
| + | AW21 | ||
| + | MW11.0 | ||
| + | MW11 | ||
| + | MX10.7 | ||
| + | T0 | ||
| + | T0.4 | ||
| + | C1 | ||
| + | C1.4 | ||
| + | </ | ||
| + | |||
| + | **S7 Arrays** | ||
| + | |||
| + | An S7 Array is configured with the size (Register Count) and starting register (Start Register), and the data type of the array is taken from the address designation. In the example | ||
| + | |||
| + | {{: | ||
| + | |||
| + | The data type is " | ||